ATMOS 14

ATMOS 14

Weather sensor with temperature measurement - ATMOS 14 - Meter Group

The ATMOS 14 is designed to measure the following:

• Air temperature

• RH

• Barometric pressure

• Vapor pressure

A rugged design allows the ATMOS 14 to withstand long-term exposure to hostile conditions, making it ideal for a wide range of applications including standard meteorological monitoring, evapotranspiration measurement, greenhouse monitoring and control, and building humidity monitoring for mold prevention and remediation.

Verify that ATMOS 14 and radiation shield (if ordered) appear in good condition.

It pertains specifically to the ATMOS 14 Gen 2, which has replaced ATMOS 14 Gen 1. The two sensor generations can be differentiated by color of the sensor body (Gen 1 is black; Gen 2 is white) and on the heat shrink label on the sensor cable. The ATMOS 14 Gen 2 is a direct drop-in replacement but represents several important improvements over its predecessor


Specifications

Relative Humidity

Range0–100% RH (0.00–1.00)
Resolution0.10% RH
AccuracySensor measurement accuracy is variable across a range of RH. Refer to the chart



This image has an empty alt attribute; its file name is image-1.png
Equilibration Time (τ, 63%)<25 s (response time in 1 m/s air stream)
Hysteresis±0.80% RH, typical
Long-Term Drift±0.25% RH/year, typical




Temperature

Range–40 to 80 °C
Resolution0.1 °C
Accuracy±0.2 °C
Equilibration Time (τ, 63%)<165 s (response time in 1 m/s air stream)
Long-Term Drift<0.03 °C/year, typical




Vapor Pressure

Range0–47 kPa
Resolution0.01 kPa
AccuracySensor measurement accuracy is variable across a range of temperatures and RH. Refer to the chart



This image has an empty alt attribute; its file name is image-2.png

Barometric Pressure

Range1–120 kPa
Resolution0.01 kPa
Accuracy±0.05 kPa at 25 °C
Equilibration Time (τ, 63%)<10 ms
Long-Term Drift<0.1 kPa/year, typical




Communication Specification

Output

DDI Serial or SDI-12 communication

Data Logger Communication

Any data acquisition system capable of 4.0- to 15.0-VDC power and serial or SDI-12 communication.


Physical Specification

Dimensions

Diameter2.0 cm (0.8 in)
Height5.4 cm (2.1 in)




Operating Temperature Range

Minimum–40 °C
TypicalNA
Maximum+80 °C



Note: Sensors may be used at higher temperatures under certain conditions; contact Customer Support for assistance.


Cable Length

5m (Standard)

75m (maximum cable length)


Cable Diameter

0.165 ±0.004 in (4.20 ±0.10 mm), with minimum jacket of 0.030 in (0.76 mm)


Connector Types

Stereo plug connector or stripped and tinned wires


Stereo Plug Connector Diameter

3.5-mm


Conductor Gauge

22-AWG / 24-AWG drain wire


Electrical and Timing Characteristics

Supply Voltage (VCC to GND)

Minimum4.0 VDC
TypicalNA
Maximum15.0 VDC




Digital Input Voltage (logic high)

Minimum2.8 V
Typical3.6 V
Maximum5.0 V




Digital Input Voltage (logic low)

Minimum-0.3 V
Typical0.0 V
Maximum0.8 V




Digital Output Voltage (logic high)

MinimumNA
Typical3.6 V
MaximumNA




Power Line Slew Rate

Minimum1.0 V/ms
TypicalNA
MaximumNA




Current Drain (during measurement)

Minimum1.2 mA
Typical3.5 mA
Maximum12.0 mA




Current Drain (while asleep)

MinimumNA
Typical0.03 mA
MaximumNA




Power Up Time (DDI Serial)

MinimumNA
TypicalNA
Maximum110 ms




Power Up Time (SDI-12)

Minimum140 ms
Typical260 ms
Maximum400 ms




Maximum400 ms Power Up Time (SDI-12, DDI Serial disabled)

MinimumNA
Typical170 ms
Maximum200 ms




Measurement Duration

MinimumNA
Typical50 ms
MaximumNA




Compliance

Manufactured under ISO 9001:2015

2004/108/EC and 2011/65/EU

EN61326-1:2013

EN50581:2012