Teros 10

Teros 10

METER TEROS 10 Soil Moisture Sensor - Team Medical & Scientific Sdn Bhd

The TEROS 10 sensor is designed to be installed in mineral soils, many types of growing
media, and other porous materials.
This manual guides the customer through the sensor features and applications and
describes how to use the sensor successfully.
• Volumetric water content (VWC) measurement
• Soil–water storage measurement
• Irrigation management
Prior to use, verify the TEROS 10 arrived in good condition. METER recommends testing the
sensors with the data logging device and software before going to the field.


Specifications

Measurement Specification

Volumetric Water Content (VWC)

Range

Mineral Soil Calibration0.00–0.64 m³/m³
Soilless Media Calibration0.0–0.7 m³/m³
Apparent dielectric permittivity (εa)1 (air) to 80 (water)
NOTE: The VWC range is dependent on the media the sensor is calibrated to.
A custom calibration will accommodate the necessary ranges for most substrates.
Resolution0.001 m³/m³

Accuracy

Mineral Soil Calibration±0.03 m³/m³ typical in mineral soils that have solution EC <8 dS/m
Soil Media Calibration±0.05 m³/m³ typical in media that has a solution EC <8 dS/m
Medium Specific Calibration±0.01–0.02 m³/m³ in any porous medium
Apparent dielectric permittivity (εa)1–40 (soil range) , ±1 εa (unitless)
40–80, 15% of measurement

Dielectric Measurement Frequency

70MHz


Communication Specifications

Output

1,000-2,500 mV


Data Logger Compatibility

Data acquisition systems capable of switched 3.0–15 VDC excitation and single-ended
voltage measurement at greater than or equal to 12-bit resolution.


Physical Specifications

Dimensions

Length5.1 cm (2.02 in)
Width2.4 cm (0.95 in)
Height7.5 cm (2.95 in)

Needle Length

5.4 cm (2.11 in)


Cable Length

5 m (standard)
40 m (maximum custom cable length)
NOTE: Contact Customer Support if a nonstandard cable length is needed.


Cable Diameter

0.165 ± 0.004 (4.20 ± 0.10 mm) with minimum jacket of 0.030 (0.76 mm)


Connector Types

Stereo plug connector or stripped and tinned wires


Stereo Plug Connector Diameter

3.50 mm


Conductor Gauge

22 AWG/24 AWG drain wire


Electrical and Timing Characteristics

Supply Voltage (VIN to GND)

Minimum3.0 VDC
TypicalNA
Maximum15.0 VDC

Operating Temperature Range

Minimum–40 °C
TypicalNA
Maximum60 °C

NOTE: Sensors may be used at higher temperatures under certain conditions; contact Customer Support for assistance.



Measurement Duration

Minimum10ms
TypicalNA
MaximumNA

COMPLIANCE
Manufactured under ISO 9001:2015
EM ISO/IEC 17050:2010 (CE Mark)
2014/30/EU and 2011/65/EU
EN61326-1:2013 and EN55022/CISPR 22

For inquiries contact us

Like and follow our facebook page at Philinstruments Corp.

Scroll to Top