ATMOS 22

ATMOS 22

ATMOS 22 | Sonic Anemometer | METER Environment

The ATMOS 22 Ultrasonic Anemometer is designed for continuous monitoring of wind speed and direction. A robust, no moving parts design that prevents errors because of wear or fouling make the ATMOS 22 ideal for long-term, remote installations.

Applications of the ATMOS 22 are listed below:

• Weather monitoring

• Microenvironment monitoring

• In-canopy wind measurement

• Spatially-distributed environmental monitoring

• Wind profiling • Crop weather monitoring

• Weather networks

Additional advantages include its low-power design that supports battery-operated data loggers, and the SDI-12 three-wire interface. A tilt sensor warns the user of out-of-level condition, and no configurations are necessary. Prior to use, verify all ATMOS 22 system components are included and appear in good condition


Specification

Measurement Specification

Horizontal Wind Speed

Range0-30 m/s
Resolution0.01 m/s
AccuracyThe greater of 0.3 m/s or 3% of measurement

Wind Gust

Range0-30 m/s
Resolution0.01 m/s
AccuracyThe greater of 0.3 m/s or 3% of measurement

Wind Direction

Range0° –359°
Resolution
Accuracy±5°

Tilt

Range–90° to 90°
Resolution0.1°
Accuracy±1°

Communication Specification

Output

SDI-12 communication

Data Logger Compatibility

METER ZL6, Em50, and EM60 data loggers or any data acquisition systems capable of 3.6- to 15.0-VDC excitation and SDI-12 communication


Physical Characteristics

Dimensions

Diameter10 cm (3.94 in)
Height16 cm (6.30 in)

Operating Temperature Range

Minimum–50 °C
TypicalNA
Maximum60 °C

Cable Length

5m (Standard)

75m (Maximum custom cable length)

NOTE: Contact Customer Support if a nonstandard cable length is needed.


Connector Types

Stereo plug connector or stripped and tinned wires


Stereo Plug Connector Diameter

3.5-mm


Electrical and Timing Characteristics

Supply Voltage (VCC to GND)

Minimum3.6 VDC continuous
TypicalNA
Maximum15.0 VDC continuous

NOTE: The ATMOS 22 must be continuously powered to work properly.

NOTE: For the ATMOS 22 to meet digital logic levels specified by SDI-12, it must be excited at 3.9 VDC or greater.


Digital Input Voltage (logic high)

Minimum2.8 V
Typical3.6 V
Maximum5.0 V

Digital Input Voltage (logic low)

Minimum-0.3 V
Typical0.0 V
Maximum0.8 V

Digital Output Voltage (logic high)

MinimumNA
Typical3.6 V
MaximumNA

Power Line Slew Rate

Minimum1.0 V/ms
TypicalNA
MaximumNA

Current Drain (during measurement)

Minimum0.2 mA
Typical8.0 mA
Maximum33.0 mA

Current Drain (while asleep)

Minimum0.2 mA
Typical0.3 mA
Maximum0.4mA

power Up Time (SDI ready)—aRx! Commands

MinimumNA
Typical10 ms
MaximumNA

power Up Time (SDI ready)—Other Commands

MinimumNA
Typical130 ms
MaximumNA

power Up Time (SDI-12, DDI disabled)

MinimumNA
Typical200 ms
MaximumNA

Measurement Duration

MinimumNA
Typical110 ms
Maximum3000 ms

Compliance

Manufactured under ISO 9001:2015

EM ISO/IEC 17050:2010 (CE Mark)

For inquiries contact us

Like and follow our facebook page at Philinstruments Corp.

Scroll to Top