Weather station for research | ATMOS 41 All-in-One Weather Station

The ATMOS 41 All-in-One Weather Station is designed for continuous monitoring of environmental variables, including all standard weather measurements (Section 3). The ATMOS 41 measures the following:

• Solar radiation

• Precipitation

• Air temperature

• Barometric pressure

• Vapor pressure

• Relative humidity

• Wind speed

• Wind direction

• Maximum wind gust

• Lightning strikes

• Lightning distance

• Tilt


All sensors are integrated into a single, small form-factor unit, requiring minimal installation effort. A robust, no moving parts design that prevents errors because of wear or fouling make the weather station ideal for long-term, remote installations. ATMOS 41 can be used for a variety of applications:

• Weather monitoring

• Microenvironment monitoring

• Spatially-distributed environmental monitoring

• Crop weather monitoring

• Fire danger monitoring

• Weather networks

Additional advantages include its low-power design that supports battery-operated data loggers and the SDI-12 three-wire interface. A tilt sensor warns the user of out-of-level condition, and no configurations are necessary.

Prior to use, verify all ATMOS 41 system components are included and appear in good condition.


Technical Specification

MEASUREMENT SPECIFICATIONS

Solar Radiation

Range0–1750 W/m²
Resolution1 W/m²
Accuracy±5% of measurement typical

Precipitation

Range0–400 mm/h
Resolution0.017 mm
Accuracy ±5% of measurement from 0 to 50 mm/h

Vapor Pressure

Range0–47 kPa
Resolution0.01 kPa
AccuracyVaries with temperature and humidity, see specification chart.

Relative Humidity

Range0–100% RH (0.00–1.00)
Resolution0.1% RH
AccuracyVaries with temperature and humidity, see specification chart.
Hysteresis±0.80% RH, typical
Long-Term Drift±0.25% RH/year, typical

Air Temperature

Range-50 to 60 °C
Resolution0.1 °C
Accuracy±0.6 °C

Humidity Sensor Temperature

Range–40 to 50 °C
Resolution0.1 °C
Accuracy±1.0 °C

Barometric Pressure

Range1–120 kPa
Resolution0.01 kPa
Accuracy±0.05 kPa at 25 °C
Equilibration< 10 ms
Long-Term Drift< 0.1 kPa/year, typical

Horizontal Wind Speed

Range0–30 m/s
Resolution0.01 m/s
AccuracyThe greater of 0.3 m/s or 3% of measurement

Wind Gust

Range0–30 m/s
Resolution0.01 m/s
AccuracyThe greater of 0.3 m/s or 3% of measurement

Wind Direction

Range0°–359°
Resolution
Accuracy±5°

Tilt

Range–90° to 90°
Resolution0.1°
Accuracy±1°

Lightning Strike

Range0–65,535 strikes
Resolution1 strike
AccuracyVariable with distance, >25% detection at <10 km typical

Lightning Average Distance

Range0–40 km
Resolution3 km
AccuracyVariable

COMMUNICATION SPECIFICATIONS

Output

SDI-12 communication

Data Logger Compatibility

METER ZL6 and EM60 data loggers or any data acquisition systems capable of switched 3.6- to 15.0-VDC excitation and SDI-12 communication


PHYSICAL CHARACTERISTICS

Dimensions

Diameter10 cm (3.9 in)
Height28 cm (11.0 in), includes rain gauge filter

Operating Temperature Range

Minimum–50 °C
TypicalNA
Maximum60 °C
NOTE: Barometric pressure and relative humidity sensors operate accurately at a minimum of –40°C.

Cable Length

  • 5 m (standard)
  • 75 m (maximum custom cable length for additional cost)
  • NOTE: Contact Customer Support if a nonstandard cable length is needed.

Connector Types

  • Stereo plug connector or stripped and tinned wires

Stereo Plug Connector Diameter

  • 3.5-mm

Conductor Gauge

  • 22-AWG / 24-AWG drain wire

Cable Diameter

  • 0.165 ±0.004 in (4.20 ±0.10 mm), with minimum jacket of 0.030 in (0.76 mm)

ELECTRICAL AND TIMING CHARACTERISTICS

Supply Voltage (VCC to GND)

Minimum3.6 VDC continuous
TypicalNA
Maximum15.0 VDC continuous
NOTE: ATMOS 41 must be continulously powered to work properly.
NOTE: For the ATMOS 41 to meet digital logic levels specified by SDI-12, it must be excited at 3.9 VDC or greater.

Digital Input Voltage (logic high)

Minimum2.8 V
Typical3.0 V
Maximum5.5 V

Digital Input Voltage (logic low)

Minimum–0.3 V
Typical0.0 V
Maximum0.8 V

Digital Output Voltage (logic high)

MinimumNA
Typical3.6 V
MaximumNA

Power Line Slew Rate

Minimum1.0 V/ms
TypicalNA
MaximumNA

Current Drain (during measurement)

Minimum0.2 mA
Typical8.0 mA
Maximum33.0 mA

Current Drain (while asleep)

Minimum0.2 mA
Typical0.3 mA
Maximum0.4 mA

Power Up Time (SDI ready)—aRx! Commands

MinimumNA
Typical10 s
MaximumNA

Power Up Time (SDI ready)—Other Commands

MinimumNA
Typical800 ms
MaximumNA

Power Up Time (SDI-12, DDI Serial disabled)

MinimumNA
Typical240 ms
MaximumNA

Measurement Duration

MinimumNA
Typical110 ms
Maximum3,000 ms

COMPLIANCE

  • Manufactured under ISO 9001:2015
  • EM ISO/IEC 17050:2010 (CE Mark)