Specifications
Measurement Specification
Volumetric Water Content (VWC)
Range
Mineral Soil Calibration | 0.00–0.64 m³/m³ |
Soilless Media Calibration | 0.0–0.7 m³/m³ |
Apparent dielectric permittivity (εa) | 1 (air) to 80 (water) |
NOTE: The VWC range is dependent on the media the sensor is calibrated to. A custom calibration will accommodate the necessary ranges for most substrates. | |
Resolution | 0.001 m³/m³ |
Accuracy
Mineral Soil Calibration | ±0.03 m³/m³ typical in mineral soils that have solution EC <8 dS/m |
Soil Media Calibration | ±0.05 m³/m³ typical in media that has a solution EC <8 dS/m |
Medium Specific Calibration | ±0.01–0.02 m³/m³ in any porous medium |
Apparent dielectric permittivity (εa) | 1–40 (soil range) , ±1 εa (unitless) 40–80, 15% of measurement |
Dielectric Measurement Frequency
70MHz
Communication Specifications
Output
1,000-2,500 mV
Data Logger Compatibility
Data acquisition systems capable of switched 3.0–15 VDC excitation and single-ended
voltage measurement at greater than or equal to 12-bit resolution.
Physical Specifications
Dimensions
Length | 5.1 cm (2.02 in) |
Width | 2.4 cm (0.95 in) |
Height | 7.5 cm (2.95 in) |
Needle Length
5.4 cm (2.11 in)
Cable Length
5 m (standard)
40 m (maximum custom cable length)
NOTE: Contact Customer Support if a nonstandard cable length is needed.
Cable Diameter
0.165 ± 0.004 (4.20 ± 0.10 mm) with minimum jacket of 0.030 (0.76 mm)
Connector Types
Stereo plug connector or stripped and tinned wires
Stereo Plug Connector Diameter
3.50 mm
Conductor Gauge
22 AWG/24 AWG drain wire
Electrical and Timing Characteristics
Supply Voltage (VIN to GND)
Minimum | 3.0 VDC |
Typical | NA |
Maximum | 15.0 VDC |
Operating Temperature Range
Minimum | –40 °C |
Typical | NA |
Maximum | 60 °C |
NOTE: Sensors may be used at higher temperatures under certain conditions; contact Customer Support for assistance.
Measurement Duration
Minimum | 10ms |
Typical | NA |
Maximum | NA |
COMPLIANCE
Manufactured under ISO 9001:2015
EM ISO/IEC 17050:2010 (CE Mark)
2014/30/EU and 2011/65/EU
EN61326-1:2013 and EN55022/CISPR 22
For inquiries contact us